经阴道四维超声造影判断输卵管通畅性、盆腔周围粘连及输卵管功能的价值
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

R711.76

基金项目:

基金项目:广州市卫生健康科技项目(编号:20201A040017)


The evaluation of tubal patency, peripelvic adhesion and tubal function by transvaginal four-dimensional contrast-enhanced ultrasonography
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的?研究阴道四维超声造影(4D-HyCoSy)评估输卵管通畅性、盆腔粘连及输卵管功能的应用价值,为临床提 供参考。方法?选取 2020 年 1 月至 8 月广州市从化区妇幼保健院收治的 96 例不孕症患者为研究对象进行回顾性分析。 以腹腔镜美兰通染液术检测结果为金标准,根据输卵管是否通畅将患者分为不通畅组(62 例)和通畅组(34 例),患者 均接受 4D-HyCoSy 检查。探讨 4D-HyCoSy 检测结果与腹腔镜检查结果的一致性,分析 4D-HyCoSy 检测结果的价值。 结果?一致性分析显示,4D-HyCoSy 判断输卵管通畅性的结果与腹腔镜检测结果一致性高(Kappa 值 =0.820,P <0.05), 4D-HyCoSy 判断输卵管通畅度的准确度为 91.67%。4D-HyCoSy 判断输卵管功能的结果与加拿大输卵管功能评分系统检测 结果一致性高(Kappa 值 =0.811,P <0.05),4D-HyCoSy 判断输卵管功能正常的准确度为 86.46%。4D-HyCoSy 与北 京协和医院盆腔粘连评分系统判断盆腔周围粘连的一致性高(Kappa 值 =0.875,P <0.05),4D-HyCoSy 判断盆腔周围粘 连的准确度为 93.75%。结论?4D-HyCoSy 评估输卵管通畅性和输卵管功能的准确性高,且有助于筛查盆腔周围粘连。

    Abstract:

    Objective?To study the application value of vaginal four-dimensional contrast-enhanced ultrasonography (4D-HyCoSy) in evaluating tubal patency, pelvic adhesion and tubal function, to provide reference for clinical practice. Methods?A retrospective analysis was conducted on 96 infertile patients admitted to Guangzhou Conghua Maternal and Child Health Hospital from January to August 2020. The patients were divided into no-unobstructed group (62 cases) and unobstructed group (34 cases), With the detection results of laparoscopic Meilantong dye solution as the gold standard, the consistency between 4D-HyCoSy test results and laparoscopy results was analyzed, the value of 4D-HyCoSy test results was analyzed. Results?The consistency analysis showed that the results of 4D-HyCoSy in judging tubal patency were highly consistent with those of laparoscopy (Kappa value =0.820, P <0.05), the accuracy of 4D-HyCoSy in judging tubal patency was 91.67%. The consistency analysis showed that the results of 4D-HyCoSy in judging tubal function were highly consistent with those of Canadian fallopian tube function scoring system (Kappa value =0.811, P <0.05), the accuracy of 4D-HyCoSy to judge the normal of fallopian tube function was 86.46% respectively. The Kappa consistency analysis showed that 4D-HyCoSy was highly consistent with the pelvic adhesion scoring system of Peking Union Medical College Hospital in judging peripelvic adhesion (Kappa = 0.875, P < 0.05). The accuracy of 4D-HyCoSy to judge the peripelvic adhesion was 93.75%. Conclusion?The 4D-HyCoSy examination has high accuracy in evaluating tubal patency and tubal function, and it is helpful to screen peripelvic adhesions.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-07-25
  • 出版日期:
文章二维码